Seismic Resistance Assessment of a Cylindrical Steel Oil Storage Tank under Different Liquid Filling Levels: A Case Study of Fergana City
DOI:
https://doi.org/10.62480/tjet.2026.vol56.pp43-48Keywords:
Steel reservoir, Seismic resistance, Structural stability, Equivalent stressAbstract
This article presents the assessment of the seismic resistance level of reservoirs used in the oil and oil-gas industry and examines the conditions required to maintain their structural stability under dynamic loading. The study includes the analysis of existing operating reservoirs using the LIRA-SAPR 10.12 software package, with particular emphasis on the evaluation of equivalent stress results. Furthermore, the distribution of equivalent stresses occurring in the plates of a cylindrical steel reservoir structure was analyzed based on calculation results obtained for liquid filling levels of 50%, 75%, and 100%.
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.
User Rights
Under the Creative Commons Attribution-NonCommercial 4.0 International (CC-BY-NC), the author (s) and users are free to share (copy, distribute and transmit the contribution).
Rights of Authors
Authors retain the following rights:
1. Copyright and other proprietary rights relating to the article, such as patent rights,
2. the right to use the substance of the article in future works, including lectures and books,
3. the right to reproduce the article for own purposes, provided the copies are not offered for sale,
4. the right to self-archive the article.